Density Meters / Portable Density & Viscosity Meter

Portable Density & Viscosity Meter VDM-250.2
VDM-250.2

- Direct density and viscosity measurement
- Density, reference density, specific gravity, API
- Automatic temperature compensation
- No sampling required
- ATEX Hazloc certification
- Safe operation, low maintenance
- At any depth up to 30 meters
- Record level, density and viscosity average per tank
- Rigid construction for heavy duty outdoor operation
- Local results storage and BLuetooth data transfer

Overview
Portable Submersible Density & Viscosity meter VDM-250 SERIES best suited for liquid density, viscosity, concentration and temperature measurements directly in the storage or process tanks (up to 30 meters depth). No labor extensive and errors critical sampling required. Instead, the sensor of VDM-250 SERIES is submersed at any required level and record spot density/viscosity and real temperature at that point directly in the liquid. The operation personal can get in minutes the average density/viscosity in the tank and its density / viscosity / temperature / level profile, for example, at every meter. Hundreds of measurements can be stored locally and future transferred to a PC or printer via built-in bluetooth connectivity. The VDM SERIES has robust design for heavy duty year round indoor or outdoor operation, even in severe climatic conditions at –40°C to +85°C (-40°F to +185°F). Backlighted LCD facilitates nighttime operation.
Documentation
file PORTABLE SUBMERSIBLE DENSITY & VISCOSITY METERS VDM-250 SERIES (VDM-250.2.pdf, 1.38 MB)
Specifications

Dynamic Viscosity Range

0.2 to 2000 mPa·s (0.2 to 2000 cP)

Dynamic Viscosity Accuracy

±1% of span

Dynamic Viscosity Repeatability

±0.5% of span

Density Range

0 to 3 g/cm³ (0 to 3000kg/m³)

Density Accuracy

Up to ±0.0003 g/cm³ (up to ±0.3 kg/m³)

Density Repeatability

Up to ±0.00015 g/cm³ (up to ±0.15 kg/m³)

Depth of submersion

Up to 30 meters (100ft.)

Temperature Range

-40°C to +85°C (-40°F to +185°F)

Temperature Accuracy

±0.1°C (±0.2°F)

Ambient temperature

-40°C to +85°C (-40°F to +185°F)

Viscosity compensation

Automatic

Temperature compensation

Automatic

Applications
- Density, viscosity & temperature profile in storage tank
- Products consistency and adulteration check
- Density and viscosity control at outlets and delivery points
- Level gauge calibration
- In-tank blending and mixing control
- Molases denisty & viscosity control in ethanol production
- % alcohol check in beverage industry
- Petroleum products, fuels, lubricants