Petroleum / In-flow Density and Viscosity Meter
            - No pressure effect
- Insensitive to plant vibration
- Continuous real time measurement
- No remote electronics
- Self-cleaning
- Low/no maintwnance
- Fast response
- Hazardous area installation
Use the proven vibrating element technique that is widely accepted as the most accurate method of continuous online density measurement, LEMIS process engineers did new step ahead introducing unique proprietary design of streamlined resonant tube that is washed on either side by measured liquid. The oscillation period of the vibrating tube and its frequency characteristics depend on behaviour of the measured liquid allowing simultaneous and accurate direct measurement of both density and dynamic viscosity, and future calculation of kinematic viscosity. An integral high accuracy Pt100 temperature probe provides liquid temperature measurement that allows calculation of reference density and viscosity.
The DC52 series sensor made from stainless steel for general industrial use or from Ni-SpanC for most demanding applications asking for ultimate accuracy in wide temperature range.
| 
             Dynamic   Viscosity Range  | 
            
             0.2 to   2000 mPa·s (0.2 to 2000 cP)  | 
        
| 
             Dynamic   Viscosity Accuracy  | 
            
             ±1% of   span  | 
        
| 
             Viscosity   Resolution  | 
            
             0.1 mPa*s   (0.1 cP)  | 
        
| 
             Dynamic   Viscosity Repeatability  | 
            
             ±0.5% of   span  | 
        
| 
             Density   Range  | 
            
             0 to 3   g/cm³ (0 to 3000kg/m³)  | 
        
| 
             Density   Accuracy  | 
            
             Up to   ±0.00025 g/cm³ (up to ±0.25 kg/m³)  | 
        
| 
             Density   Resolution  | 
            
             ±0.0001   g/cm³ (±0.1 kg/m³)  | 
        
| 
             Density   Repeatability  | 
            
             Up to   ±0.000125 g/cm³ (up to ±0.125 kg/m³)  | 
        
| 
             Temperature   Range  | 
            
             -200°C to   +200°C (-328°F to +392°F)  | 
        
| 
             Temperature   Accuracy  | 
            
             ±0.2°C   (±0.4°F)  | 
        
| 
             Pressure   Range  | 
            
             Up to 100   Bar  | 
        
| 
             Ambient   temperature  | 
            
             -40°C to   +85°C (-40°F to +185°F)  | 
        
| 
             Viscosity   compensation  | 
            
             Automatic  | 
        
| 
             Temperature   compensation  | 
            
             Automatic  | 
        
- Pipeline interface detection
- Quench oil control
- Fuel oil heater control
- Oil and petrochemical
- Marine industry
- General industries